Why a PCCP needs a quality-system home

An authorized PCCP tells FDA what you will change and how. It does not, by itself, create the records that prove each change was made that way. Since February 2, 2026, those records live under the Quality Management System Regulation, which incorporates ISO 13485:2016 by reference.

FDA's final PCCP guidance expects modifications to be implemented in accordance with your quality system. This kit gives you the crosswalk: which clause owns each PCCP element, what the record must show, and who owns it.

This Cahir MedTech workbook is an illustrative planning aid, not an FDA-endorsed mapping. It pairs with the AI/ML PCCP Suite, which helps you build the PCCP itself.

The core crosswalk

Swipe horizontally to see all columns.

PCCP elementISO 13485:2016 clauseRecord that proves it
SPS modification description7.3.3 Design inputsControlled input with performance bounds
ACP performance evaluation7.3.6 / 7.3.7 Verification and validationLocked-test-set results vs acceptance criteria
ACP update procedures7.3.8 Transfer, 7.5.1Release, deployment and rollback records

The full crosswalk, with tracking fields, is included in the paid kit.

Treat every update as a controlled design change

Clause 7.3.9 requires design changes to be reviewed, verified, validated and approved before implementation. A PCCP pre-authorizes the regulatory side; it does not waive the design-change record.

The Modification Execution Log captures, for each change: the SPS item it falls under, the evaluation that confirms it stayed inside the boundary, the V&V record, the DHF update and the approval. If a change falls outside the PCCP, the same evaluation documents why a new submission is needed.

Link algorithm risk to the risk file

Drift thresholds and stop conditions are risk controls. The Risk Linkage tab ties each algorithm failure mode to its SPS item, control, threshold and ISO 14971 risk file reference, so a reviewer can see why a threshold was set where it was.

Close the loop with feedback and CAPA

Real-world performance monitoring is QMSR feedback (8.2.1) and data analysis (8.4). When a metric breaches a stop condition, the Monitoring and CAPA tab routes it to nonconformance (8.3) and CAPA (8.5.2) and records the deployment hold or rollback.

Rehearse the inspection questions

Under Compliance Program 7382.850 an investigator may ask you to walk from a deployed model version back to the authorized PCCP. The Inspection Checklist tab lists six likely questions and where the evidence should live, so your team can rehearse retrieval before anyone asks.

Frequently asked questions

Does a PCCP replace design change control?

No. A PCCP removes the need for a new marketing submission for planned changes, but each change is still a controlled design change under ISO 13485 clause 7.3.9.

Is this mapping endorsed by FDA?

No. It is an illustrative crosswalk prepared from the QMSR and FDA's PCCP guidance. Confirm it with qualified quality and regulatory reviewers for your device.

Do I need the AI/ML PCCP Suite too?

Only if you are still building the PCCP. This kit assumes you have, or are drafting, an authorized PCCP and need to run it inside your QMS.

What does it cost?

$199 USD one-time per company workspace. Applicable taxes may apply.